黄金城集团

    QIAGEN DNeasy PowerSoil Pro Kit

    QIAGEN

    Published: 2023-04-07 DOI: 10.17504/protocols.io.kxygx97mzg8j/v1
    AI 解读
    浏览 1882

    Abstract

    For the isolation of microbial genomic DNA from all soil types, including difficult samples such as compost, sediment, and manure.

    The DNeasy PowerSoil Pro Kit comprises a novel and proprietary method for isolating microbial genomic DNA from environmental samples. The kit uses QIAGEN’s secondgeneration Inhibitor Removal Technology® (IRT) and is intended for use with environmental samples containing high humic acid content, including difficult soil types such as compost, sediment, and manure. Other more common soil and stool types have also been used successfully with this kit. Improved IRT combined with more efficient bead beating and lysis chemistry yields high-quality DNA that can be used immediately in downstream applications, including PCR, qPCR, and next-generation sequencing (16S and whole genome).

    As of April, 2023 - no published studies successfully detecting fish sedDNA using only this kit (see Lakes ABPS protocol). Unpublished studies report poor DNA yields and low concentrations of fish sedDNA. Other studies targeting migratory fish sedDNA during a spawning run found sufficient fish sedDNA concentrations following this protocol.

    Before start

    Ensure that the PowerBead Pro Tubes rotate freely in the centrifuge without rubbing.* If Solution CD3 has precipitated, heat at 60°C until precipitate dissolves.

    • Perform all centrifugation steps at room temperature (15–25°C).

    Steps

    Sample preparation & cell lysis

    1.

    SPIN the PowerBead Pro Tube briefly to ensure that the beads have settled at the bottom

    ADD up to 0.25g of soil sample to the PowerBead Pro Tube

    ADD 800µL of Solution CD1

    VORTEX briefly to mix

    2.

    HOMOGENIZE samples thoroughly using one of the following methods:

    2.1.

    SECURE the PowerBead Pro Tube horizontally on a Vortex Adapter for 1.5–2 ml tubes

    VORTEX at maximum speed for 0h 10m 0s

    2.2.

    USING a PowerLyzer 24 Homogenizer, homogenize the soil at 2000rpm,0h 0m 0s for

    PAUSE for 0h 0m 30s

    HOMOGENIZE again at 2000rpm,0h 0m 0s for 0h 0m 30s

    2.3.

    USING a TissueLyser II, place the PowerBead Pro Tube into the TissueLyser Adapter

    FASTEN the adapter into the instrument and shake for 0h 5m 0s at speed 25 Hz

    REORIENT the adapter so that the side that was closest to the machine body is now furthest from it

    SHAKE again for 0h 5m 0s at a speed of 25 Hz.

    3.

    CENTRIFUGE the PowerBead Pro Tube at 15000x g,0h 0m 0s for 0h 1m 0s

    TRANSFER supernatant to a clean 2 mL Microcentrifuge Tube (expect 500-600ul)

    Inhibitor removal

    4.

    ADD 200µL of Solution CD2

    VORTEX for 0h 0m 5s

    5.

    CENTRIFUGE tubes at 15000x g,0h 0m 0s for 0h 1m 0s

    AVOIDING the pellet, transfer up to 700µL of supernatant to a clean 2 ml Microcentrifuge Tube

    Bind DNA

    6.

    ADD 600µL of Solution CD3

    VORTEX for 0h 0m 5s

    7.

    LOAD 650µL of the lysate onto an MB Spin Column

    CENTRIFUGE at 15000x g,0h 0m 0s for 0h 1m 0s

    DISCARD the liquid flow-through

    8.

    REPEAT step 7 to ensure that all of the lysate has passed through the MB Spin Column

    CAREFULLY place the MB Spin Column into a clean 2 mL Collection Tube. Avoid splashing any flow-through onto the MB Spin Column

    Wash spin column

    9.

    ADD 500µL of Solution EA to the MB Spin Column

    CENTRIFUGE at 15000x g,0h 0m 0s for 0h 1m 0s

    DISCARD the flow-through and place the MB Spin Column into the same 2 mL Collection Tube

    10.

    ADD 500µL of Solution C5 to the MB Spin Column

    CENTRIFUGE at 15000x g,0h 0m 0s for 0h 1m 0s

    DISCARD the flow-through and place the MB Spin Column into a NEW 2 mL Collection Tube

    11.

    CENTRIFUGE at 16000x g,0h 0m 0s for 0h 2m 0s

    CAREFULLY place the MB Spin Column into a new 1.5 ml Elution Tube

    Elute the DNA

    12.

    ADD between 50µL and 100µL of Solution C6 to the center of the white filter membrane

    CENTRIFUGE at 15000x g for 0h 1m 0s

    DISCARD the MB Spin Column

    DNA is now ready for downstream applications